Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
  Name SKU Description Category
Fluke 3585R Split-Core Current Transformers Current range: 0.5 – 1-0A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke 373 True-RMS 600A/600V AC Clamp Meters 600 A ac current measurement with fixed jaw 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement to 6000Ω with continuity detection 1000 µF capacitance measurement State of the art signal processing allows for use in noisy electrical environments while providing stable readings Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch... Current Clamp Meters
Fluke 365 True-rms AC Clamp Meter with Detachable 18mm Jaw 200A ac and dc current measurement with detach-able jaw 600V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals 6000Ω resistance measurement with continuity detection Detachable jaw makes accessing wires and viewing the display easier Built in flashlight/torch allows for easy illumination and identification of wires CAT III 600V safety rating Compact design fits in your hand and can be used while wearing personal protective... Current Clamp Meters
Fluke 323 400A AC, 600V AC/DC True-RMS Clamp Meter 400 A AC current measurement 600 V AC & DC voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement up to 40 kΩ with continuity detection Features: Slim, ergonomic design CAT IV 300V/CAT III 600 V safety rating Hold button Two-year warranty Soft carrying case Current Clamp Meters
Fluke 324 40/400A AC, 600V AC/DC True-RMS Clamp Meter with Temperature, & Capacitance Measurements 400 A AC current measurement 600 V AC & DC voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement up to 40 kΩ with continuity detection Temperature and capacitance measurement Features: Slim, ergonomic design Backlight display CAT IV 300V/CAT III 600 V safety rating Hold button Two-year warranty Soft carrying case Current Clamp Meters
Fluke 325 40/400A AC/DC, 600V AC/DC True-RMS Clamp Meter with Frequency, Temperature, & Capacitance Measurements 400 A ac and dc current measurement 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement up to 40 kΩ with continuity detection Temperature and capacitance measurement Frequency measurement Min/Max functionality Features: Slim, ergonomic design Backlight display CAT IV 300V/CAT III 600 V safety rating Hold button Two-year warranty Soft carrying case Current Clamp Meters
Fluke 353 AC/DC TRMS 2000 A Clamp Meter; Amps Only For Voltage Measurements, See : Fluke 355 Clamp Meters Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors CAT IV 600 V, CAT III 1000 V rating for added user protection In-rush current measurement captures 'power-on' surge current with accuracy and repeatability Accurately measure frequency up to 1 kHz for optimum troubleshooting Quickly analyze readings using the MIN, MAX, and AVG functions A... Current Clamp Meters
Fluke 355 AC/DC TRMS 2000 A Clamp Meter See Also: Fluke 353 Clamp meter Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors CAT IV 600 V, CAT III 1000 V rating for added user protection In-rush current measurement captures 'power-on' surge current with accuracy and repeatability Accurately measure frequency up to 1 kHz for optimum troubleshooting Quickly analyze readings using the MIN, MAX, and AVG functions A... Current Clamp Meters
Fluke 374 600A/600V True-RMS AC/DC Clamp Meter 600A AC and DC current measurement with fixed jaw 2500 A ac current measurement with iFlex flexible current probe (sold separately) 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement of 6000 Ω with continuity detection Min, max, average and inrush recording to capture variations automatically 500 mV dc measurement range to interface with other CAT IV 600V, CAT III 1000 V safety rating iFlex... Current Clamp Meters
Fluke 375 600A/600V True-RMS AC/DC Clamp Meter with Frequency Measurement 600A AC and DC current measurement with fixed jaw 2500 A ac current measurement with iFlex flexible current probe (sold separately) 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement to 60 kΩ with continuity detection Min, max, average and inrush recording to capture variations automatically 500 mV dc measurement range to interface with other CAT IV 600V, CAT III 1000 V safety rating Frequency... Current Clamp Meters
Fluke 376 1000A/1000V True-RMS AC/DC Clamp Meters 1000 A AC and DC current measurement with fixed jaw 2500 A AC current measurement with iFlex flexible current probe 1000 V AC and DC voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Frequency measurement to 500 Hz with both jaw and iFlex 60 kΩ resistance measurement with continuity detection Min, max, average and inrush recording to capture variations automatically 500 mV dc measurement range to interface with other accessories 1000... Current Clamp Meters
Fluke 381 Remote Display True-rms AC/DC Clamp Meter with 18-inch iFlex 1000 A AC/DC current measurement with fixed jaw 2500 A AC current measurement with iFlex flexible current probe 1000 V ac and dc voltage measurement True-RMS AC voltage and current for accurate measurements on non-linear signals Frequency measurement to 500 Hz with both jaw and iFlex 60 kΩ resistance measurement with continuity detection Min, max, average and inrush recording to capture variations automatically Wireless technology allows the display to be carried up to 30 ft away from... Current Clamp Meters
Fluke 360 AC Leakage Clamp Meter Measurement of leakage current with 3 mA range and 1 µA of resolution, for accurate monitoring of insulation erosion Broad range of measurement, from 1 µA up to 60 A, for all installation needs Advanced shielding to ensure accurate results when measuring near other conductors The high durability clamp construction can withstand over 50,000 operations - added ruggedness that extends the life of your clamp Easy-to-carry, pocket-sized clamp with wide 40 mm (1.5 in) jaw size Handy... Current Clamp Meters
Fluke 345 Power Quality Clamp Meter AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics Verify... Current Clamp Meters